smartctl 6.5 (build date Sep 26 2022) [x86_64-linux-4.4.302+] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate IronWolf Pro
Device Model:     ST16000NT001-3LV101
Serial Number:    ZR5CNRN5
LU WWN Device Id: 5 000c50 0e5b56a61
Firmware Version: EN01
User Capacity:    16,000,900,661,248 bytes [16.0 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   Unknown(0x0fe0) (minor revision not indicated)
SATA Version is:  SATA >3.2 (0x1ff), 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Aug  5 13:28:24 2026 -05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  567) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (1415) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x50bd)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME                                                   FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate                                              0x000f   079   064   044    Pre-fail  Always       -       74845969
  3 Spin_Up_Time                                                     0x0003   088   087   000    Pre-fail  Always       -       0
  4 Start_Stop_Count                                                 0x0032   100   100   020    Old_age   Always       -       277
  5 Reallocated_Sector_Ct                                            0x0033   100   100   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate                                                  0x000f   081   060   045    Pre-fail  Always       -       124437434
  9 Power_On_Hours                                                   0x0032   099   099   000    Old_age   Always       -       1175
 10 Spin_Retry_Count                                                 0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count                                                0x0032   100   100   020    Old_age   Always       -       206
 18 Head_Health                                                      0x000b   100   100   050    Pre-fail  Always       -       0
187 Reported_Uncorrect                                               0x0032   100   100   000    Old_age   Always       -       0
188 Command_Timeout                                                  0x0032   100   100   000    Old_age   Always       -       0 0 0
190 Airflow_Temperature_Cel                                          0x0022   056   054   000    Old_age   Always       -       44 (Min/Max 30/44)
192 Power-Off_Retract_Count                                          0x0032   100   100   000    Old_age   Always       -       29
193 Load_Cycle_Count                                                 0x0032   100   100   000    Old_age   Always       -       834
194 Temperature_Celsius                                              0x0022   044   046   000    Old_age   Always       -       44 (0 16 0 0 0)
197 Current_Pending_Sector                                           0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable                                            0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count                                             0x003e   200   200   000    Old_age   Always       -       0
200 Pressure_Limit                                                   0x0023   100   100   001    Pre-fail  Always       -       0
240 Head_Flying_Hours                                                0x0000   100   253   000    Old_age   Offline      -       778h+13m+19.551s
241 Total_LBAs_Written                                               0x0000   100   253   000    Old_age   Offline      -       93031002412
242 Total_LBAs_Read                                                  0x0000   100   253   000    Old_age   Offline      -       308404922179

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.